Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
JACC Cardiovasc Interv ; 17(6): 756-767, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38385926

RESUMO

BACKGROUND: Intravascular lithotripsy (IVL) has demonstrated effectiveness in the treatment of calcified lesions in selected patients with stable coronary disease. OBJECTIVES: The authors sought to assess the performance of coronary IVL in calcified coronary lesions in a real-life, all comers, setting. METHODS: The REPLICA-EPIC18 study prospectively enrolled consecutive patients treated with IVL in 26 centers in Spain. An independent core laboratory performed the angiographic analysis and event adjudication. The primary effectiveness endpoint assessed procedural success (successful IVL delivery, final diameter stenosis <20%, and absence of in-hospital major adverse cardiovascular events [MACE]). The primary safety endpoint measured freedom from MACE at 30 days. A predefined substudy compared outcomes between acute coronary syndrome (ACS) and chronic coronary syndrome (CCS) patients. RESULTS: A total of 426 patients (456 lesions) were included, 63% of the patients presenting with ACS. IVL delivery was successful in 99% of cases. Before IVL, 49% of lesions were considered undilatable. The primary effectiveness endpoint was achieved in 66% of patients, with similar rates among CCS patients (68%) and ACS patients (65%). Likewise, there were no significant differences in angiographic success after IVL between CCS and ACS patients. The rate of MACE at 30 days (primary safety endpoint) was 3% (1% in CCS and 5% in ACS patients [P = 0.073]). CONCLUSIONS: Coronary IVL proved to be a feasible and safe procedure in a "real-life" setting, effectively facilitating stent implantation in severely calcified lesions. Patients with ACS on admission showed similar angiographic success rates but showed a trend toward higher 30-day MACE compared with patients with CCS. (REPLICA-EPIC18 study [Registry of Coronary Lithotripsy in Spain]; NCT04298307).


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Humanos , Vasos Coronários , Estudos Prospectivos , Resultado do Tratamento , Coração , Litotripsia/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
2.
Microvasc Res ; 150: 104598, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37633337

RESUMO

In the 20th century, research focused on cholesterol and lipoproteins as the key mechanism in establishing atherosclerotic cardiovascular disease (ASCVD). Given that some studies demonstrated subclinical atherosclerosis in subjects without conventional cardiovascular risk factors, the elevated low-density lipoprotein (LDL) levels alone cannot account for the entire burden of atherosclerosis. Hence, large-scale clinical trials demonstrated the operation of immune and inflammatory pathways in ASCVD. In this regard, the evidence establishes that cells of the immune system, both the innate (neutrophils, macrophages) and adaptive (T cell and other lymphocytes) limbs, contribute to atherosclerosis and atherothrombosis. Besides, basic science studies have identified proatherogenic cytokines such as interleukin (IL)-1, IL-12, and IL-18. In this regard, some studies showed that antiinflammatory therapy targeting the immune system by modulating or blocking interleukins, also known as anti-cytokine therapy, can reduce the risk of major cardiovascular adverse events. The neutrophils play a key role in the innate immune system, representing the acute phase of an inflammatory response. In contrast, lymphocytes represent the adaptive immune system and promote the induction of autoimmune inflammation, especially in the chronic inflammatory response. Through the literature review, we will highlight the inflammatory pathway for the physiopathology of ASCVD, HF, and COVID-19. In this regard, the neutrophil-to-lymphocyte ratio (NLR) integrates the innate immune and adaptive immune systems, making the NLR a biomarker of inflammation. In addition, we provided an update on the evidence showing that high NLR is associated with worse prognosis in heart failure (HF), ASCVD, and COVID-19, as well as their clinical applications showing that the normalization of NLR after anti-cytokine therapy is a potential predictor of therapy responsiveness and is associated with reduction of major adverse cardiovascular events.


Assuntos
Aterosclerose , COVID-19 , Doenças Cardiovasculares , Insuficiência Cardíaca , Humanos , Doenças Cardiovasculares/diagnóstico , Neutrófilos , Prognóstico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Linfócitos , Biomarcadores , Doença Crônica
3.
Catheter Cardiovasc Interv ; 101(3): 651-654, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36691874

RESUMO

Coronary fistulas are not common in patients undergo coronary angiography. It is described, even less frequently, that coronary fistulas may be associated with giant aneurysms along their course. These cases classically are treated surgically. We present a case treated fully percutaneously in a novel fashion.


Assuntos
Aneurisma Coronário , Seio Coronário , Fístula , Humanos , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/terapia , Resultado do Tratamento , Angiografia Coronária , Fístula/complicações
6.
Catheter Cardiovasc Interv ; 100(7): 1286-1290, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36273418

RESUMO

OBJECTIVES: The aim of this study was to describe the procedural and early outcomes of patients with mechanical mitral valve prosthesis (MVP) undergoing transcatheter aortic valve replacement (TAVR) with a novel self-expandable retrievable device. BACKGROUND: TAVR in patients with prior MVP may have an increased risk of complications related to device positioning and interference between both prosthetic valves. METHODS: An observational study was conducted, including eight patients with severe symptomatic aortic stenosis and prior mechanical MVP who underwent TAVR with the novel device AllegraTM (Biosensors). No transesophageal monitoring was used. RESULTS: The mean age of the study population was 75 years. The mean distance between MVP and aortic annulus was 3.8 mm. Procedural success was achieved in all patients with no major intraprocedural, in-hospital, or follow-up complications. CONCLUSIONS: TAVR with Allegra TAVI system in patients with prior MVP offers good procedural and clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Desenho de Prótese , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Int J Surg Case Rep ; 99: 107659, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36116308

RESUMO

INTRODUCTION AND IMPORTANCE: Various artifacts mimicked aortic dissection, such as streak artifacts generated by high-attenuation material, high-contrast interfaces, cardiac motion, periaortic structures, aortic wall motion, and normal aortic sinuses, have been described in the literature. Most artifacts that simulate ascending aortic dissection occur frequently on conventional CT. Their position is predictable and is related to systolic aortic motion. However, so far, to the best of our knowledge, this is the first pseudo-aortic dissection reported during coronary angiography in cardiac arrest. CASE PRESENTATION: We report a case of a middle-aged man transferred to our hospital after an out-of-hospital cardiac arrest. The coronary angiography revealed non-obstructive coronary arteries and an image of probable aortic dissection was observed. Given the persistent asystole despite a prolonged advance cardiopulmonary resuscitation and the possibility of aortic dissection, a prompt in-room heart team discussion was performed. It was decided to stop and withdraw potentially life-sustaining treatment due to futility. The necropsy study revealed the aorta with some mild atherosclerotic plaques but without either aneurysm or thrombosis. The coronary arteries were reported as with patency, but in the proximal left anterior descending artery (LAD), the intima layer presented a thickness that decreased 50 % of the luminal area without signs of complicated acute plaques. CLINICAL DISCUSSION: In this case, the systolic aortic motion theory cannot explain the false-aortic dissection image in the coronary angiography because the patient was under cardiac arrest. Studies with arterial and venous pressures devices recording in cardiac arrest, demonstrated an abnormal hemodynamic flow, suggesting that the hemodynamic flow might be backward during cardiopulmonary resuscitation Therefore, in the setting of this abnormal hemodynamic flow, the injection of contrast may have an abnormal distribution and flow in the aorta creating an image of pseudo-aortic dissection. CONCLUSION: Although the exact mechanism of this false-positive aortic dissection in cardiac arrest remains unknown, operators should be aware of this entity during coronary angiography in the setting of cardiac arrest with mechanical chest compressions to avoid diagnostic errors in clinical practice.

8.
Ann Noninvasive Electrocardiol ; 27(6): e12998, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35904538

RESUMO

BACKGROUND: Since the last century, the electrocardiogram (ECG) remains the non-invasive test, that is, most easily accessible, feasible, and inexpensive for cardiology assessment. In past years, many novel ECG indexes and patterns have been published that allow for a more advanced evaluation of what is currently being done, especially based on subtle QRS changes and patterns. OBJECTIVE: The objective of the study was to provide an update on the evidence and clinical applications of these ECG subtle QRS changes and patterns associated with heart disease. METHODS: Through the literature review, we will highlight the subtle QRS changes and patterns associated with heart disease, mainly focusing on QRS duration, voltage, morphology, axis, and QT interval. RESULTS: Small increases in QRS duration are associated with a reduction in left ventricular ejection fraction (EF), increased cardiac chamber dimensions, and risk for incident heart failure (HF). Moreover, fragmentation of the QRS complex is associated with myocardial fibrosis and is a substrate for developing arrhythmic events. Besides, low amplitude QRS voltage is associated with congestive HF, and an increase in the voltage of the QRS complexes is associated with the effectiveness of diuresis treatment. Furthermore, small increases in QT interval are associated with diastolic dysfunction due to impaired sarcoplasmic reticulum calcium handling as occurs in myocardial ischemia, hypertension, or diabetes. On the other hand, in patients with left ventricular dysfunction, the QRS area is associated with clinical and echocardiographic response to cardiac resynchronization therapy regardless of the type of bundle branch block. In addition, subtle ECG changes and patterns in the left bundle branch block are associated with concomitant right ventricular dilation, mostly based on the QRS axis and voltage. Notwithstanding, to identify these subtle changes in QRS require exact manual measurements that can take time. In this regard, applying artificial intelligence (AI) to the ECG can make a quicker and more complete assessment, as well as provide a low cost when applied to large populations. CONCLUSION: We provided an update on the evidence and clinical applications of these subtle QRS changes and patterns associated with diastolic dysfunction, reduced EF, and HF development and therapy responsiveness, as well as their applications for AI to ECG.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico/fisiologia , Eletrocardiografia/métodos , Função Ventricular Esquerda/fisiologia , Inteligência Artificial , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Bloqueio de Ramo , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Arritmias Cardíacas
9.
Biomolecules ; 12(1)2022 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-35053224

RESUMO

The angiotensin-converting enzyme 2 (ACE2) is a type I integral membrane that exists in two forms: the first is a transmembrane protein; the second is a soluble catalytic ectodomain of ACE2. The catalytic ectodomain of ACE2 undergoes shedding by a disintegrin and metalloproteinase domain-containing protein 17 (ADAM17), in which calmodulin mediates the calcium signaling pathway that is involved in ACE2 release, resulting in a soluble catalytic ectodomain of ACE2 that can be measured as soluble ACE2 plasma activity. The shedding of the ACE2 catalytic ectodomain plays a role in cardiac remodeling and endothelial dysfunction and is a predictor of all-cause mortality, including cardiovascular mortality. Moreover, considerable evidence supports that the ACE2 catalytic ectodomain is an essential entry receptor for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Additionally, endotoxins and the pro-inflammatory cytokines interleukin (IL)-1ß and tumor necrosis factor-alpha (TNFα) all enhanced soluble catalytic ectodomain ACE2 shedding from the airway epithelia, suggesting that the shedding of ACE2 may represent a mechanism by which viral entry and infection may be controlled such as some types of betacoronavirus. In this regard, ACE2 plays an important role in inflammation and thrombotic response, and its down-regulation may aggravate COVID-19 via the renin-angiotensin system, including by promoting pathological changes in lung injury. Soluble forms of ACE2 have recently been shown to inhibit SARS-CoV-2 infection. Furthermore, given that vitamin D enhanced the shedding of ACE2, some studies reported that vitamin D treatment is associated with prognosis improvement in COVID-19. This is an updated review on the evidence, clinical, and therapeutic applications of ACE2 for COVID-19.


Assuntos
Enzima de Conversão de Angiotensina 2/metabolismo , COVID-19/metabolismo , Sinalização do Cálcio , Sistema Renina-Angiotensina , SARS-CoV-2/metabolismo , Domínio Catalítico , Humanos
11.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1032-1041, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33158760

RESUMO

INTRODUCTION AND OBJECTIVES: Aortic self-expandable (SE) transcatheter aortic valve implantation (TAVI) devices are particularly useful for patients with aortic stenosis and small/tortuous vessels, small aortic annuli, or low coronary ostia. However, it is unclear whether the growing range of SE devices shows comparable hemodynamic and clinical outcomes. We aimed to determine the differential hemodynamic (residual valve area and regurgitation) and clinical outcomes of these devices in comparable scenarios. METHODS: All patients were enrolled from 4 institutions and were managed with 4 different SE TAVI devices. Baseline and follow-up clinical data were collected and echocardiographic tests blindly and centrally analyzed. Patients were compared according to valve type and a 1:1 matched comparison was performed according to degree of calcification, aortic annulus dimensions, left ventricular ejection fraction, and body surface area. RESULTS: In total, 514 patients were included (Evolut R/PRO, 217; ACURATE neo, 107; ALLEGRA, 102; Portico, 88). Surgical risk scores were comparable in the unmatched population. No differences were observed in the post-TAVI regurgitation rate and in in-hospital mortality (2.7%). The rate of pacemaker implantation at discharge was significantly different among devices (P=.049), with Portico showing the highest rate (23%) and ACURATE neo the lowest (9.5%); Evolut R/PRO and ALLEGRA had rates of 15.9% and 21.2%, respectively. The adjusted comparison showed worse residual TAVI gradients and aortic valve area with ACURATE neo vs ALLEGRA (P=.001) but the latter had higher risk of valve embolization and a tendency for more cerebrovascular events. CONCLUSIONS: A matched comparison of 4 SE TAVI devices showed no differences regarding residual aortic regurgitation and in-hospital mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
Rev. esp. cardiol. (Ed. impr.) ; 71(5): 357-364, mayo 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178533

RESUMO

Introducción y objetivos: Muchos pacientes sometidos a implante percutáneo de válvula aórtica (TAVI) presentan insuficiencia mitral (IM) de grado moderado o menor. El impacto de la insuficiencia tricuspídea (IT) sigue sin resolverse. Se analiza el impacto de la IM moderada frente a leve-ausente y su evolución, y de la IT concomitante y su interacción con la IM. Métodos: Estudio retrospectivo multicéntrico de 813 pacientes tratados con TAVI entre 2007 y 2015 con IM ≤ 2 y abordaje transfemoral. Resultados: La edad media fue 81 ± 7 años y el Society of Thoracic Surgeons-score fue de 6,9 ± 5,1%. El 37,3% presentó IM moderada, con resultados comparables intrahospitalarios y de mortalidad a 6 meses frente a IM < 2 (11,9 frente a 9,4%; p = 0,257). Sin embargo, experimentaron más rehospitalizaciones y peor clase de la New York Heart Association (p = 0,008 y 0,001, respectivamente). Solo un 3,8% demostró un aumento en el grado de IM > 2 tras el TAVI. La presencia de IT moderada/grave se asoció con una mortalidad intrahospitalaria y de seguimiento del 13 y el 34,1%, independientemente del grado de IM. La IT moderada-grave fue predictor independiente de mortalidad (HR = 18,4; IC95%, 10,2-33,3; p < 0,001). Conclusiones: La presencia de IM moderada no supuso mayor mortalidad a corto-medio plazo tras el TAVI, pero asoció más rehospitalizaciones. La presencia de IT moderada/grave implicó mayor mortalidad. Esto sugiere que una evaluación minuciosa de los mecanismos subyacentes entre ambas insuficiencias valvulares debe realizarse para determinar la mejor estrategia para evitar la futilidad relacionada con TAVI


Introduction and objectives: Many patients undergoing transcatheter aortic valve implantation (TAVI) have concomitant mitral regurgitation (MR) of moderate grade or less. The impact of coexistent tricuspid regurgitation (TR) remains to be determined. We sought to analyze the impact of moderate vs none-to-mild MR and its trend after TAVI, as well as the impact of concomitant TR and its interaction with MR. Methods: Multicenter retrospective study of 813 TAVI patients treated through the transfemoral approach with MR ≤ 2 between 2007 and 2015. Results: The mean age was 81 ± 7 years and the mean Society of Thoracic Surgeons score was 6.9% ± 5.1%. Moderate MR was present in 37.3% of the patients, with similar in-hospital outcomes and 6-month follow-up mortality to those with MR < 2 (11.9% vs 9.4%; P = .257). However, they experienced more rehospitalizations and worse New York Heart Association class (P = .008 and .001, respectively). Few patients (3.8%) showed an increase in the MR grade to > 2 post-TAVI. The presence of concomitant moderate/severe TR was associated with in-hospital and follow-up mortality rates of 13% and 34.1%, respectively, regardless of MR grade. Moderate-severe TR was independently associated with mortality (HR, 18.4; 95%CI, 10.2-33.3; P < .001). Conclusions: The presence of moderate MR seemed not to impact short- and mid-term mortality post-TAVI, but was associated with more rehospitalizations. The presence of moderate or severe TR was associated with higher mortality. This suggests that a thorough evaluation of the mechanisms underlying concomitant mitral and tricuspid valve regurgitation should be performed to determine the best strategy for avoiding TAVI-related futility


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Mitral/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco
13.
Catheter Cardiovasc Interv ; 92(5): 935-944, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29314570

RESUMO

AIMS: Empirically, transfemoral (TF) approach is the first choice for transcatheter aortic valve implantation (TAVI). We aimed to investigate whether transubclavian (TSc) and TF approaches present comparable major outcomes according to current evidence. METHODS: We systematically searched PubMed, EMBASE, and Cochrane database for studies with symptomatic aortic stenosis patients who underwent TAVI through TF or TSc/axillary access from January/2006 to January/2017. Searched terms were: ("aortic stenosis" OR "transcatheter aortic" OR "TAVI" OR "TAVR") and ("transfemoral" OR "transaxillary" OR "transubclavian"). Major outcomes according to Valve Academic Research Consortium-2 criteria were gathered. The odds ratio (OR) was used as a summary statistic. A random-effects model was used. A fully percutaneous TSc TAVI case from our institution illustrates minimalist approach. RESULTS: Final analysis was made with six studies including 4,504 patients (3,886 TF and 618 TSc). Baseline characteristics of compared groups in individual studies were similar, with the exception of a higher logistic EuroSCORE in the TSc group (23.7 ± 1.92 vs. 21.17 ± 3.51, P = 0.04) and higher prevalence of coronary and peripheral artery disease with OR = 0.67 [95% CI: 0.54-0.83] (P = 0.0003) and OR = 0.08 [95% CI: 0.05-0.12] (P < 0.00001), respectively. TSc group presented comparable 30-day mortality (OR = 1.37; [95%CI: 0.85-2.21]; P = 0.20). There were no differences for procedural success, 30-day stroke rate, need for new pacemaker implantation, major vascular complications, and acute kidney injury requiring dialysis. Also, no differences were found concerning 1-year mortality. CONCLUSIONS: Our study suggests that TSc approach may be, not only an alternative route to TF approach for TAVI, but even a competitive one in certain patients with increased risk of femoral injury.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral , Artéria Subclávia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Humanos , Masculino , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
Rev Esp Cardiol (Engl Ed) ; 71(5): 357-364, 2018 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29079280

RESUMO

INTRODUCTION AND OBJECTIVES: Many patients undergoing transcatheter aortic valve implantation (TAVI) have concomitant mitral regurgitation (MR) of moderate grade or less. The impact of coexistent tricuspid regurgitation (TR) remains to be determined. We sought to analyze the impact of moderate vs none-to-mild MR and its trend after TAVI, as well as the impact of concomitant TR and its interaction with MR. METHODS: Multicenter retrospective study of 813 TAVI patients treated through the transfemoral approach with MR ≤ 2 between 2007 and 2015. RESULTS: The mean age was 81 ± 7 years and the mean Society of Thoracic Surgeons score was 6.9% ± 5.1%. Moderate MR was present in 37.3% of the patients, with similar in-hospital outcomes and 6-month follow-up mortality to those with MR < 2 (11.9% vs 9.4%; P = .257). However, they experienced more rehospitalizations and worse New York Heart Association class (P = .008 and .001, respectively). Few patients (3.8%) showed an increase in the MR grade to > 2 post-TAVI. The presence of concomitant moderate/severe TR was associated with in-hospital and follow-up mortality rates of 13% and 34.1%, respectively, regardless of MR grade. Moderate-severe TR was independently associated with mortality (HR, 18.4; 95%CI, 10.2-33.3; P < .001). CONCLUSIONS: The presence of moderate MR seemed not to impact short- and mid-term mortality post-TAVI, but was associated with more rehospitalizations. The presence of moderate or severe TR was associated with higher mortality. This suggests that a thorough evaluation of the mechanisms underlying concomitant mitral and tricuspid valve regurgitation should be performed to determine the best strategy for avoiding TAVI-related futility.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ecocardiografia Doppler em Cores , Mortalidade Hospitalar , Insuficiência da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/métodos , Causas de Morte , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Análise Multivariada , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Taxa de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade
15.
JACC Cardiovasc Interv ; 10(19): 1973-1981, 2017 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-28982562

RESUMO

OBJECTIVES: The aim of this study was to determine the prognosis and specific complications of patients with prosthetic mitral valves (PMVs) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR is performed relatively often in patients with PMVs, but specific risks are not well described. METHODS: A multicenter analysis was conducted, including patients with severe symptomatic aortic stenosis who underwent TAVR at 10 centers. Patients' clinical characteristics and outcomes were evaluated according to the presence of a PMV. RESULTS: The mean age of the study population (n = 2,414) was 81 ± 8 years, and 48.8% were men. A total of 91 patients (3.77%) had PMVs. They were more commonly women, younger, and had higher surgical risk. PMVs were implanted a median of 14 years before TAVR, and most patients had mechanical prostheses (73.6%). Eighty-six patients (94.5%) were on long-term vitamin K inhibitor therapy, and bridging antithrombotic therapy was administered in 59 (64.8%). TAVR device embolization occurred in 6.7% (vs. 3.3% in the non-PMV group; p = 0.127), in all instances when distance between the PMV and the aortic annulus was <7 mm. Mortality rates did not show a difference, but the rate of bleeding was higher in patients with PMV (24.2% vs. 16.1%; p = 0.041), even in those treated via the transfemoral approach (22.2% vs. 13.9%; p = 0.048). Indeed, bleeding complications, prior atrial fibrillation, chronic obstructive pulmonary disease, surgical risk, and New York Heart Association functional class were independent predictors of mortality. CONCLUSIONS: TAVR presents similar mortality irrespective of the presence of a PMV. However, patients with PMVs had higher bleeding risk that was independently associated with higher mortality. Risk for valve embolization was relatively high, but it occurred only in patients with PMV-to-aortic annulus distances <7 mm.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 9(24): 2527-2538, 2016 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-27889349

RESUMO

OBJECTIVES: The aim of this study was to describe the incidence, mechanisms, features, and management of aseptic intracardiac shunts (AICS). BACKGROUND: AICS following transcatheter aortic valve replacement (TAVR) are an uncommon and barely described complication. METHODS: A systematic review was performed of all published cases of AICS following TAVR, and the incidence, predictors, main features, management, and related outcomes were analyzed. RESULTS: A total of 31 post-TAVR AICS were gathered. After excluding transapical fistulas, the 28 remaining cases corresponded with an incidence of about 0.5%. Mean age and mean logistic European System for Cardiac Operative Risk Evaluation score were 80 ± 11 years and 19.2 ± 8.3%, respectively. Prior radiation therapy for cancer was present in 14.3%, and 42.8% had severe calcification of the aortic valve. TAVR was undertaken using balloon-expandable prostheses in the majority of cases (85.7%), via the transapical approach in one-third. Median time from TAVR to diagnosis was 21 days (interquartile range: 7 to 30 days), with intraprocedural suspicion in 12 cases (42.9%) and a mean Qp/Qs ratio of 1.8 ± 0.6. The most common location for AICS was the interventricular septum (60.7%). Heart failure was frequent (46.4%), but 14 patients (50%) remained asymptomatic. Medical treatment (71.4%) was associated with poor outcomes (30-day mortality rate 25%), especially in symptomatic patients (35% vs. 0%; p = 0.020) and in those with higher Qp/Qs ratios (1.9 ± 0.6 vs. 1.4 ± 0.1), while cardiac surgery (3.6%), and percutaneous closure (25%) led to good outcomes after a median follow-up period of 3 months (interquartile range: 1 to 9 months). CONCLUSIONS: Post-TAVR AICS are uncommon but have high 30-day mortality if left untreated, especially in symptomatic patients. Percutaneous closure was feasible and safe in symptomatic patients but remains controversial in asymptomatic subjects.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Circulação Coronária , Cardiopatias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Cardiopatias/mortalidade , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Incidência , Masculino , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...